Power Specifications Approximate current consumption at 12 volts DC Approximate current consumption at 24 volts DC
SkyView system
no backup battery
3.5 amps 1.8 amps
SkyView system
with backup battery
+1.5 amps additional
during battery charging
+0.7 amps additional
during battery charging

Physical Specifications - English Dimensions Weight
SV-D700 7.64" W x 5.51" H x 2.14" D 2.4 lb.
SV-D1000 10.32" W x 7.06" H x 2.14" D 3.0 lb.
SV-ADAHRS-200 and
SV-ADAHRS-201
4.71" W x 1.22" H x 2.61" D 8.2 oz.
SV-EMS-220 6.35" W x 1.09" H x 2.99" D 9.6 oz.
SV-GPS-250 2.19" W x 0.75" H x 3.44" D 6.7 oz.
SV-BAT-320 3.30" W x 2.10" H x 3.90" D 13.1 oz.

Physical Specifications - Metric Dimensions Weight
SV-D700 19.4cm W x 14.0cm H x 5.4cm D 1.09kg
SV-D1000 26.2cm W x 17.9cm H x 5.4cm D 1.36kg
SV-ADAHRS-200 and
SV-ADAHRS-201
12.0cm W x 3.1cm H x 6.6cm D 0.23kg
SV-EMS-220 16.1cm W x 2.8cm H x 7.6cm D 0.27kg
SV-GPS-250 5.6cm W x 1.9cm H x 8.7cm D 0.19kg
SV-BAT-320 8.4cm W x 5.3cm H x 9.9cm D 0.37kg

Environmental Specifications Storage Temperature Operating Temperature
SV-D700 -40 °C to +70 °C -30 °C to +60 °C
SV-D1000 -40 °C to +70 °C -30 °C to +60 °C
SV-ADAHRS-200 and
SV-ADAHRS-201
-40 °C to +70 °C -30 °C to +60 °C
SV-EMS-220 -40 °C to +70 °C -30 °C to +60 °C
SV-GPS-250 -40 °C to +70 °C -40 °C to +60 °C
SV-BAT-320 -20 °C to +60 °C Charge: 0 °C to +45 °C
Discharge: -20 °C to +60 °C